NFG SERIES – AUTO/MANUAL – 0.7M³ TO 2.8M³

SEA-FIRE NovecTM 1230 NFG fire extinguishing systems are designed to protect enclosed machinery spaces. All NFG systems operate automatically by heat activation. Discharge occurs when the sensing valve temperature rises into the system activation range indicated on the nameplate attached to each unit. Manual triggering is also possible on units with the "M" designation.

NFG systems are designed to produce a minimum atmospheric concentration of 5.85% within the protected area. Each system is equipped with a factory-installed pressure switch designed to monitor cylinder pressure and can also be used to control other electrical functions (engine shutdown, air exchange devices, i.e. fans and blowers, etc.).

Approved for marine use in sizes from 0.7m³ to 2.8m³ engine compartment volume.


NFD SERIES – AUTO/MANUAL – 3.5M³ TO 51M³

SEA-FIRE NovecTM 1230 NFD fire extinguishing systems are designed to protect enclosed machinery spaces. All NFD systems operate automatically by heat activation. Discharge occurs when the temperature of the sensing valve rises into the system activation range indicated on the nameplate attached to each unit. Manual triggering is also possible for units with the "M" designation.

NFD systems are designed to produce a minimum atmospheric concentration of 5.85% in the protected chamber. Each system is equipped with a factory-installed pressure switch designed to monitor cylinder pressure and can also be used to control other electrical functions (engine shutdown, air exchange devices, i.e. fans and blowers, etc.).

Marine-approved in sizes from 3.5 m³ up to 51 m³ engine compartment volume.

NMG SERIES – MANUAL ONLY – 0.7M³ TO 5.7M³

SEA-FIRE NovecTM 1230 NMG fire extinguishing systems are designed for the protection of enclosed machinery spaces. All NFG systems are manual only with release via a manual release cable.

NFG systems are designed to provide a minimum atmospheric concentration of 5.85% within the protected space. Each system is fitted with a factory-installed pressure switch designed to monitor cylinder pressure and can also be used to control other electrical functions (engine shutdown, air exchange devices i.e. fans and blowers etc.).

Approved for marine use in sizes from 0.7m³ to 5.7m³ engine compartment volume.

NMD SERIES – MANUAL ONLY – 6.4M³ TO 51M³

SEA-FIRE NovecTM 1230 NMD fire suppression systems are designed to protect enclosed machinery spaces. All NMD systems are manual only with release via a manual release cable.

NMD systems are designed to produce a minimum atmospheric concentration of 5.85% within the protected space. Each system is equipped with a factory-installed pressure switch pressure switch designed to monitor cylinder pressure and also to control other electrical functions (engine shutdown, air, air exchange devices, i.e. fans and blowers, etc.).

Marine-approved in sizes from 6.4m³ to 51.0m³ engine compartment volume.